Type of Appliance
Gas Hot Water Continious Flow System
Type of Operation
With or without remote controls
Exhaust System
Forced Fan – Type D
Model Number
VECC85-30E5
Dimensions
Height – 590 x W384 x Depth 181, Weight 20Kg
Max Consumption
LPG – 183,8Mj/h (3,75Kg/h)
NG – 60kw
Gas Connection
22mm
Cold Water Connection
22mm
Hot Water Connection
22mm
Ignition System
Electronic Pulse
Electrical Consumption
Normal – 60.0 watt
Standby – 6.0 watt
Anti Frost Protection – 100 watt
Thermal Efficiency
90.0%
Temperature Range
With Controller – 36 85 degrees C
Default – 57 degrees or last set temperature
Minimum Start-up Water Pressure
20 kpa
Maximum Start-up Water Pressure
100 kpa
Minimum Water flow rate for Start-up
4lt per minute
Power Supply
Appliance – 240 Volts 50Hz
Remote Control – DC 12 Volts (Digital)
Safety Device: 30L –
Over Current
Combustion Fan rpm check
Pressure Relief Valve
Glas Fuse (3 amp)